Title: | Core Meteorological Measurements for the APEX Alpha Fen Bonanza Creek Experimental Forest: 2007-2011 |
Contacts: |
Cable, William L Conlin, Molly Kane, Evan Treat, Claire C Turetsky, Merritt R Waddington, J. |
Abstract: | Air temperature, relitive humidity, barometric pressure, net radiation, and precipitation were recorded every half hour at the APEX alpha Fen. APEX Fen is located in the Bonanza Creek LTER outside of Fairbanks, AK. APEX Fen uses a full-factorial water table (flooded or raised, lowered or drained, and control treatments, as well as a moisture gradient) by warming manipulation (warmed, unwarmed treatment). |
Methods: | Data were recorded with a Campbell CR1000 datalogger. Air temperature and relitive humidity were measured using a HMP Vaisala sensor, precipitation was measured using a tipping bucket rain gauge (TE525WS) and net radiation was measured using a Q7.1 REBS Net Radiometer. |
Experimental Design: | This site provides core meteorological data for the APEX alpha fen. |
Supplemental Documentation: | None on file. |
Corrections: | None on file. |
Supplemental Acknowledgements: | None on file. |
Keywords: | experimental warming, peatland, soil climate manipulation, soil temperature, water table manipulation, wetlands |
Categories: | Climate |
Study Period: | 2007-06-22 to 2011-12-31 |
Sampling Frequency: | scanned every 20 seconds and reported every 30-min (every 10-min after 2008-06-26). |
Bounding Box: |
West Longitude: -148.31034° |
Site References: |
Site ID: apexcon |
Data Columns: |
Column: 1 Column: 2 Column: 3 Column: 4 Column: 5 Column: 6 Column: 7 Column: 8 |
Public Release: | 2012-03-18 |